Microfluidics · 2010
A simple method of fabricating mask-free microfluidic devices for biological analysis
We report a simple, low-cost, rapid, and mask-free method to fabricate two-dimensional (2D) and three-dimensional (3D) microfluidic chip for biological analysis researches. In this fabrication process, a laser system is used to cut through paper to form intricate patterns and differently configured channels for specific purposes.
Performance the paper reports
0 of 5- Motion—Motion accuracy: not reported
- Volume—Volumetric accuracy: not reported
- Viability—Cell viability: not reported
- Unattended—Unattended operation: not reported
- Standard—Standard compliance: not reported
The full text was read and states no figure for any of the five.
How hard this is to adopt
3.3 of 5, higher is easierEach score is shown against the range the other 59 builds actually occupy, because no criterion uses the full 1–5 scale. These describe how reproducible the build is, not how good the science is.
Resolution
3/1–5Smallest feature/positioning evidence about 50-100 µm.
Throughput
2/2–5Operation appears single-unit or manually constrained.
Parts sourcing
3/2–4Part sourcing complexity not explicit; assigned moderate default.
Skill needed
4/2–4Build/operation described as low-skill or basic assembly.
Facilities needed
3/2–4Requires accessible but nontrivial lab/maker equipment.
Documentation
3/2–5Some open documentation or files are available.
Validation effort
4/2–4Validation includes standards, benchmarking, replicates, or multi-condition tests.
Cycle time
4/1–4Speed evidence suggests rapid, real-time, or automated operation.
2 further criteria are recorded but not shown
- Application Level — scored 2 (75% of records share one value), so it cannot separate one build from another.
- Build Time (scored for only 6 of 60 records), so it cannot separate one build from another.
Both remain in the published dataset.
Have you built this?
Report what it took, including attempts that stalled. A failed build tells the next laboratory what the documentation leaves out.
Know what this record is missing?
The index has no cost, licence on the design files, link to the design files or which files exist (CAD, bill of materials, firmware…) for this build. If you are an author or have built it, you know; a GitHub issue pre-filled with this record takes a minute.
Record metadata
Publication data
Matched by title · retrieved 2026-07-21
Abstract
We report a simple, low-cost, rapid, and mask-free method to fabricate two-dimensional (2D) and three-dimensional (3D) microfluidic chip for biological analysis researches. In this fabrication process, a laser system is used to cut through paper to form intricate patterns and differently configured channels for specific purposes. Full abstract at the publisher
Bibliographic details
Access and metrics
Topics and keywords
Perspective and practical signals
Why it matters
No narrative note curated yet.
Limitations
No limitation note curated yet.