All builds

Microfabrication · 2020 · Micromachines

Hydrogel Patterns in Microfluidic Devices by Do-It-Yourself UV-Photolithography Suitable for Very Large-Scale Integration

The interest in large-scale integrated (LSI) microfluidic systems that perform high-throughput biological and chemical laboratory investigations on a single chip is steadily growing. Such highly integrated Labs-on-a-Chip (LoC) provide fast analysis, high functionality, outstanding reproducibility at low cost per sample, and small demand of reagents.

Performance the paper reports

0 of 5
  1. Motion—Motion accuracy: not reported
  2. Volume—Volumetric accuracy: not reported
  3. Viability—Cell viability: not reported
  4. Unattended—Unattended operation: not reported
  5. Standard—Standard compliance: not reported

The full text was read and states no figure for any of the five.

How hard this is to adopt

2.7 of 5, higher is easier

Each score is shown against the range the other 59 builds actually occupy, because no criterion uses the full 1–5 scale. These describe how reproducible the build is, not how good the science is.

  • Resolution

    4/1–5

    Smallest feature/positioning evidence about 20 µm.

  • Throughput

    2/2–5

    Operation appears single-unit or manually constrained.

  • Parts sourcing

    2/2–4

    Requires specialized or custom-built components.

  • Skill needed

    2/2–4

    Multiple advanced technical skills appear required.

  • Facilities needed

    2/2–4

    Requires specialized facilities, equipment, or consumables.

  • Documentation

    3/2–5

    Some open documentation or files are available.

  • Validation effort

    4/2–4

    Validation includes standards, benchmarking, replicates, or multi-condition tests.

  • Cycle time

    not scored

    No speed envidence.

2 further criteria are recorded but not shown
  • Application Level — scored 2 (75% of records share one value), so it cannot separate one build from another.
  • Build Time (scored for only 6 of 60 records), so it cannot separate one build from another.

Both remain in the published dataset.

Have you built this?

Report what it took, including attempts that stalled. A failed build tells the next laboratory what the documentation leaves out.

Report a rebuild

Know what this record is missing?

The index has no cost, licence on the design files, link to the design files or which files exist (CAD, bill of materials, firmware…) for this build. If you are an author or have built it, you know; a GitHub issue pre-filled with this record takes a minute.

Fill the gap
Record metadata
Publication data

Matched by doi · retrieved 2026-09-23

Abstract

The interest in large-scale integrated (LSI) microfluidic systems that perform high-throughput biological and chemical laboratory investigations on a single chip is steadily growing. Such highly integrated Labs-on-a-Chip (LoC) provide fast analysis, high functionality, outstanding reproducibility at low cost per sample, and small demand of reagents. One LoC platform technology capable of LSI relies on specific intrinsically active polymers, the so-called stimuli-responsive hydrogels. Analogous to microelectronics, the active components of the chips can be realized by photolithographic micro-patterning of functional layers. The miniaturization potential and the integration degree of the microfluidic circuits depend on the capability of the photolithographic process to pattern hydrogel layers with high resolution, and they typically require expensive cleanroom equipment. Here, we propose, compare, and discuss a cost-efficient do-it-yourself (DIY) photolithographic set-up suitable to micro-pattern hydrogel-layers with a resolution as needed for very large-scale integrated (VLSI) microfluidics. The achievable structure dimensions are in the lower micrometer scale, down to a feature size of 20 µm with aspect ratios of 1:5 and maximum integration densities of 20,000 hydrogel patterns per cm². Furthermore, we demonstrate the effects of miniaturization on the efficiency of a hydrogel-based microreactor system by increasing the surface area to volume (SA:V) ratio of integrated bioactive hydrogels. We then determine and discuss a correlation between ultraviolet (UV) exposure time, cross-linking density of polymers, and the degree of immobilization of bioactive components.

Bibliographic details

Published
2020-05-02
Journal/source
Micromachines
Publisher
MDPI AG
DOI
10.3390/mi11050479
Type
journal-article
Language
en
Volume / issue
11 / 5
Pages
479
ISSN
2072-666X

Access and metrics

Open access
Yes
OA status
gold
License
cc-by
Version
publishedVersion
Cited by
28
References
51
Retracted
No

Authors and affiliations

  1. Anthony BeckTechnische Universität Dresden
  2. Franziska ObstLeibniz Institute of Polymer Research
  3. Mathias BusekTechnische Universität Dresden
  4. Stefan GrünznerTechnische Universität Dresden
  5. Philipp Jan MehnerTechnische Universität Dresden
  6. Georgi PaschewTechnische Universität Dresden
  7. Dietmar AppelhansLeibniz Institute of Polymer Research
  8. Brigitte I. VoitLeibniz Institute of Polymer Research · Technische Universität Dresden
  9. Andreas RichterCorresponding authorTechnische Universität Dresden

Topics and keywords

Microfluidic and Capillary Electrophoresis Applications3D Printing in Biomedical ResearchInnovative Microfluidic and Catalytic Techniques InnovationMicrofluidicsMiniaturizationPhotolithographyNanotechnologySelf-healing hydrogelsMaterials scienceMicrotechnologyMicroelectronicsIntegrated circuitOptoelectronics
Perspective and practical signals

Why it matters

DIY UV-photolithography setup for patterning stimuli-responsive hydrogels at very-large-scale integration density (20,000 patterns/cm2, 20 um features) without cleanroom equipment.

Limitations

Requires specialized/custom-built photolithography components and multiple advanced technical skills; no code/hardware repository provided.