Modular microfluidic systems cast from 3D-printed molds for imaging leukocyte adherence to differentially treated endothelial cultures
Supplemental record retained to make the downloaded paper corpus fully navigable.
- Year
- —
- Skill
- medium
- Docs
- moderate
- Rubric
- 3.3 / 5
Implementation assessment
Scoring by criterion
Scores describe accessibility and implementation characteristics reported in the reviewed source. They are not a measure of scientific quality.
Resolution
Smallest feature/positioning evidence about 100 um.
Scalability/Throughput
Evidence of parallel, plate-scale, multi-head, or unattended operation.
Build and Part Sourcing Complexity
Mix of common parts and custom/printed components.
Skill Complexity
Build/operation described as low-skill or basic assembly.
Equipment/Cosumable/Facility Requirement Accessibility
Requires specialized facilities, equipment, or consumables.
Application Level
Presented as modular or usable across multiple workflows.
Accessibility to documentation
Some open documentation or files are available.
Validation/Troubleshooting Complexity
Validation includes standards, benchmarking, replicates, or multi-condition tests.
Speed/Cycle Time
No clear speed comparison found; assigned neutral score.
Build Time
Build time not reported; assigned neutral score.
Record metadata
Publication data
Crossref and OpenAlex
Publication record
Abstract
Microfluidic systems are very useful for in vitro studies of interactions between blood cells and vascular endothelial cells under flow, and several commercial solutions exist. However, the availability of customizable, user-designed devices is largely restricted to researchers with expertise in photolithography and access to clean room facilities. Here we describe a strategy for producing tailor-made modular microfluidic systems, cast in PDMS from 3D-printed molds, to facilitate studies of leukocyte adherence to endothelial cells. A dual-chamber barrier module was optimized for culturing two endothelial cell populations, separated by a 250 μm wide dividing wall, on a glass slide. In proof-of-principle experiments one endothelial population was activated by TNFα, while the other served as an internal control. The barrier module was thereafter replaced with a microfluidic flow module, enclosing both endothelial populations in a common channel. A suspension of fluorescently-labeled leukocytes was then perfused through the flow module and leukocyte interactions with control and TNFα-treated endothelial populations were monitored in the same field of view. Time-lapse microscopy analysis confirmed the preferential attachment of leukocytes to the TNFα-activated endothelial cells. We conclude that the functionality of these modular microfluidic systems makes it possible to seed and differentially activate adherent cell types, and conduct controlled side-by-side analysis of their capacity to interact with cells in suspension under flow. Furthermore, we outline a number of practical considerations and solutions associated with connecting and switching between the microfluidic modules, and the advantages of simultaneously and symmetrically analyzing control and experimental conditions in such a microfluidic system.
Bibliographic details
Access and metrics
Topics and keywords
Perspective and practical signals
Why it matters
Supplemental record retained to make the downloaded paper corpus fully navigable.
Limitations
Metadata is limited to the download manifest and title-derived mapping.