µPump: An open-source pressure pump for precision fluid handling in microfluidics
Supplemental record retained to make the downloaded paper corpus fully navigable.
- Year
- —
- Skill
- medium
- Docs
- moderate
- Rubric
- 3.5 / 5
Implementation assessment
Scoring by criterion
Scores describe accessibility and implementation characteristics reported in the reviewed source. They are not a measure of scientific quality.
Resolution
Quantitative handling accuracy reported, but minimum volume unclear.
Scalability/Throughput
Evidence of parallel, plate-scale, multi-head, or unattended operation.
Build and Part Sourcing Complexity
Mostly off-the-shelf or kit-based components.
Skill Complexity
Build/operation described as low-skill or basic assembly.
Equipment/Cosumable/Facility Requirement Accessibility
Uses common benchtop/desktop equipment or generic consumables.
Application Level
Presented as modular or usable across multiple workflows.
Accessibility to documentation
Open build documentation is not clearly identified.
Validation/Troubleshooting Complexity
Validation includes standards, benchmarking, replicates, or multi-condition tests.
Speed/Cycle Time
No clear speed comparison found; assigned neutral score.
Build Time
Build time not reported; assigned neutral score.
Linked tools
Record metadata
Publication data
Crossref and OpenAlex
Publication record
Abstract
An open-source precision pressure pump system and control software is presented, primarily designed for the experimental microfluidics community, although others may find additional uses for this precision pressure source. This mechatronic system is coined 'µPump,' and its performance rivals that of commercially available systems, at a fraction of the cost. The pressure accuracy, stability, and resolution are 0.09%, 0.02%, and 0.02% of the full span, respectively. The settling time to reach 2 bar from zero and stabilize is less than 2 s. Material for building a four-channel µPump (approx. $3000 USD) or an eight-channel µPump (approx. $5000 USD) is approximately a quarter, or a third of the cost of buying a high-end commercial system, respectively. The design rationale is presented, together with documented design details and software, so that the system may be replicated or customized to particular applications. µPump can be used for two-phase droplet microfluidics, single-phase microfluidics, gaseous flow microfluidics and any other applications requiring precise fluid handling. µPump provides researchers, students, and startups with a cost-effective solution for precise fluid control.
Bibliographic details
Access and metrics
Topics and keywords
Funding
- University of Waterloo
- Waterloo Institute for Nanotechnology, University of Waterloo
- Ontario Centres of Excellence
- Natural Sciences and Engineering Research Council of Canada
Perspective and practical signals
Why it matters
Supplemental record retained to make the downloaded paper corpus fully navigable.
Limitations
Metadata is limited to the download manifest and title-derived mapping.