Adapting a Low-Cost and Open-Source Commercial Pipetting Robot for Nanoliter Liquid Handling
Supplemental record retained to make the downloaded paper corpus fully navigable.
- Year
- —
- Skill
- medium
- Docs
- moderate
- Rubric
- 3.6 / 5
Implementation assessment
Scoring by criterion
Scores describe accessibility and implementation characteristics reported in the reviewed source. They are not a measure of scientific quality.
Resolution
Minimum volume evidence about 0.015 uL.
Scalability/Throughput
Evidence of parallel, plate-scale, multi-head, or unattended operation.
Build and Part Sourcing Complexity
Mix of common parts and custom/printed components.
Skill Complexity
Build/operation described as low-skill or basic assembly.
Equipment/Cosumable/Facility Requirement Accessibility
Requires accessible but nontrivial lab/maker equipment.
Application Level
Presented as modular or usable across multiple workflows.
Accessibility to documentation
Open build documentation is not clearly identified.
Validation/Troubleshooting Complexity
Validation includes standards, benchmarking, replicates, or multi-condition tests.
Speed/Cycle Time
Speed evidence suggests rapid, real-time, or automated operation.
Build Time
Build time not reported; assigned neutral score.
Record metadata
Publication data
Crossref and OpenAlex
Publication record
Abstract
Low-volume liquid handling capabilities in bioanalytical workflows can dramatically improve sample processing efficiency and reduce reagent costs, yet many commercial nanoliter liquid handlers cost tens of thousands of dollars or more. We have successfully adapted a low-cost and open-source commercial pipetting robot, the Opentrons OT-1, to accurately aspirate and dispense nanoliter volumes. Based on fluorescence measurements, the modified OT-1 was able to reproducibly transfer 50 nL of water with less than 3% measurement error and 5% coefficient of variation (CV). For 15 nL transfers, the volume measurements indicated less than 4% error and 4% CV. We applied this platform to the preparation of low-nanogram proteomic samples for liquid chromatography-mass spectrometry analysis, demonstrating that the modified OT-1 is an effective platform for nanoliter liquid handling. At a total materials cost of less than $6000, including the commercial liquid handler and all modifications, this system is also far less expensive than other platforms with similar capabilities, placing automated nanoliter handling within reach of a far broader scientific community.
Bibliographic details
Access and metrics
Topics and keywords
Funding
- National Cancer Institute · R33CA225248
Perspective and practical signals
Why it matters
Supplemental record retained to make the downloaded paper corpus fully navigable.
Limitations
Metadata is limited to the download manifest and title-derived mapping.