Evaluation of Microplate Handling Accuracy for Applying Robotic Arms in Laboratory Automation
Quantifies robot-arm positioning requirements for microplate transfer—key enabler around liquid handlers.
- Year
- 2024
- Skill
- low
- Docs
- limited
- Rubric
- 3.5 / 5
Implementation assessment
Scoring by criterion
Scores describe accessibility and implementation characteristics reported in the reviewed source. They are not a measure of scientific quality.
Resolution
Quantitative handling accuracy reported, but minimum volume unclear.
Scalability/Throughput
Evidence of parallel, plate-scale, multi-head, or unattended operation.
Build and Part Sourcing Complexity
Mix of common parts and custom/printed components.
Skill Complexity
Build/operation described as low-skill or basic assembly.
Equipment/Cosumable/Facility Requirement Accessibility
Requires accessible but nontrivial lab/maker equipment.
Application Level
Presented as modular or usable across multiple workflows.
Accessibility to documentation
Some open documentation or files are available.
Validation/Troubleshooting Complexity
Validation includes standards, benchmarking, replicates, or multi-condition tests.
Speed/Cycle Time
Speed evidence suggests rapid, real-time, or automated operation.
Build Time
Build time not reported; assigned neutral score.
Record metadata
Publication data
Crossref and OpenAlex
Publication record
Abstract
ABSTRACT An inexpensive single-arm robot is widely utilized for recent laboratory automation solutions. The integration of a single-arm robot as a transfer system into a semi-automatic liquid dispenser without a transfer system can be realized as an inexpensive alternative to a fully automated liquid handling system. However, there has been no quantitative investigation of the positional accuracy of robot arms required to transfer microplates. In this study, we constructed a platform comprising aluminum frames and digital gauges to facilitate such measurements. We measured the position repeatability of a robot arm equipped with a custom-made finger by repeatedly transferring microplates. Further, the acceptable misalignment of plate transfer was evaluated by adding an artificial offset to the microplate position using this platform. The results of these experiments are expected to serve as benchmarks for the selection of robot arms for laboratory automation in biology. Furthermore, all information for replicating this device will be made publicly available, thereby allowing many researchers to collaborate and accumulate knowledge, hopefully contributing to advances in this field.
Bibliographic details
Access and metrics
Topics and keywords
Perspective and practical signals
Why it matters
Quantifies robot-arm positioning requirements for microplate transfer—key enabler around liquid handlers.
Limitations
No limitation note curated yet.