Real-time AI-driven quality control for laboratory automation: a novel computer vision solution for the opentrons OT-2 liquid handling robot
Abstract The adoption of robotics and automated solutions in life sciences R&D has accelerated in recent years, driven by the need to process increasing sample volumes, protect laboratory staff from hazardous substances, and manage financial pressures. Various automation systems, each with distinct levels of sample processing, transportation tasks, and data management, are available to meet specific application requirements, with liquid handling robots taking pivotal positions in these systems.
Performance the paper reports
0 of 5- Motion—Motion accuracy: not reported
- Volume—Volumetric accuracy: not reported
- Viability—Cell viability: not reported
- Unattended—Unattended operation: not reported
- Standard—Standard compliance: not reported
The full text was read and states no figure for any of the five.
How hard this is to adopt
3.1 of 5, higher is easierEach score is shown against the range the other 59 builds actually occupy, because no criterion uses the full 1–5 scale. These describe how reproducible the build is, not how good the science is.
Resolution
3/1–5Vision volume estimation validated only over 50-270 uL (3.4% mean error, 95% accuracy) with P20 tips imaged at 10/20 uL; sub-10 uL capability is the host OT-2 and unmeasured.
Throughput
5/2–5Host OT-2 8-channel arm imaged with all eight tips and mapped across a 12x8 96-well plate, a parallel multi-tip head, though channels are not independently controlled.
Parts sourcing
3/2–4Part sourcing complexity not explicit; assigned moderate default.
Skill needed
2/2–4Multiple advanced technical skills appear required.
Facilities needed
3/2–4Requires accessible but nontrivial lab/maker equipment.
Documentation
3/2–5Some open documentation or files are available.
Validation effort
3/2–450 live runs, 100 volume tests, mAP@50 of 0.995, 98% missing-tip accuracy and regression calibration, but Table 5 compares only to a prior YOLOv5 paper, not a conventional or manual benchmark.
Cycle time
3/1–4Only 1.1 s/frame versus 8 s for the prior AI method; no timing comparison reported against manual pipetting or a commercial handler, and vision adds per-step overhead.
2 further criteria are recorded but not shown
- Application Level — scored 4 (75% of records share one value), so it cannot separate one build from another.
- Build Time (scored for only 6 of 60 records), so it cannot separate one build from another.
Both remain in the published dataset.
Have you built this?
Report what it took, including attempts that stalled. A failed build tells the next laboratory what the documentation leaves out.
Know what this record is missing?
The index has no cost, licence on the design files, link to the design files or which files exist (CAD, bill of materials, firmware…) for this build. If you are an author or have built it, you know; a GitHub issue pre-filled with this record takes a minute.
Record metadata
Publication data
Matched by doi · retrieved 2026-07-21
Abstract
Abstract The adoption of robotics and automated solutions in life sciences R&D has accelerated in recent years, driven by the need to process increasing sample volumes, protect laboratory staff from hazardous substances, and manage financial pressures. Various automation systems, each with distinct levels of sample processing, transportation tasks, and data management, are available to meet specific application requirements, with liquid handling robots taking pivotal positions in these systems. However, current liquid handling robots, such as the Opentrons OT-2, lack integrated vision-based quality control, which limits their accuracy and reliability. This study presents an AI-driven computer vision model designed to enhance quality control in laboratory automation. By integrating the YOLOv8 object detection model with the OT-2, our model enables precise detection of pipette tips and liquid volumes, providing real-time feedback on errors, such as missing tips and incorrect liquid levels. Our results demonstrate the model's effectiveness and accessibility, presenting an affordable solution for improving automation in academic and research laboratories. This closed-loop system transforms the OT-2 into a robust tool for automated laboratory tasks, making it an accessible and cost-effective approach for enhancing quality control in laboratory automation and addressing a critical gap in available tools for resource-limited settings.
Bibliographic details
Access and metrics
Topics and keywords
Funding
- Technical University of Denmark
Perspective and practical signals
Why it matters
No narrative note curated yet.
Limitations
No limitation note curated yet.