Liquid Handling · 2019
An open-source programmable smart pipette for portable cell separation and counting
Microfluidics offers great potential for biomedical applications, but the complexity, inconvenience, and low pumping equipment accessibility of operating microfluidic devices have limited their widespread use. Here we describe an open-source, programmable smart (OS) pipette as an easy-to-use, simple, handheld microfluidic pump that overcomes the major limitations of previous commercial- or research-level pumps for microfluidics.
Performance the paper reports
0 of 5- Motion—Motion accuracy: not reported
- Volume—Volumetric accuracy: not reported
- Viability—Cell viability: not reported
- Unattended—Unattended operation: not reported
- Standard—Standard compliance: not reported
The full text was read and states no figure for any of the five.
How hard this is to adopt
3.5 of 5, higher is easierEach score is shown against the range the other 59 builds actually occupy, because no criterion uses the full 1–5 scale. These describe how reproducible the build is, not how good the science is.
Resolution
3/1–5Quantitative handling accuracy reported, but minimum volume unclear.
Throughput
4/2–5Evidence of parallel, plate-scale, multi-head, or unattended operation.
Parts sourcing
3/2–4Mix of common parts and custom/printed components.
Skill needed
4/2–4Build/operation described as low-skill or basic assembly.
Facilities needed
3/2–4Requires accessible but nontrivial lab/maker equipment.
Documentation
3/2–5Some open documentation or files are available.
Validation effort
4/2–4Validation includes standards, benchmarking, replicates, or multi-condition tests.
Cycle time
4/1–4Speed evidence suggests rapid, real-time, or automated operation.
2 further criteria are recorded but not shown
- Application Level — scored 4 (75% of records share one value), so it cannot separate one build from another.
- Build Time (scored for only 6 of 60 records), so it cannot separate one build from another.
Both remain in the published dataset.
Have you built this?
Report what it took, including attempts that stalled. A failed build tells the next laboratory what the documentation leaves out.
Know what this record is missing?
The index has no cost or link to the design files for this build. If you are an author or have built it, you know; a GitHub issue pre-filled with this record takes a minute.
Record metadata
Publication data
Matched by doi · retrieved 2026-07-21
Abstract
Microfluidics offers great potential for biomedical applications, but the complexity, inconvenience, and low pumping equipment accessibility of operating microfluidic devices have limited their widespread use. Here we describe an open-source, programmable smart (OS) pipette as an easy-to-use, simple, handheld microfluidic pump that overcomes the major limitations of previous commercial- or research-level pumps for microfluidics. The OS pipette pumps fluid into a microfluidic device by precisely controlling the position of the plunger of a positive-displacement micropipette with stepper motor control. The intuitive pumping mechanism of the OS pipette enables the novel features of simple fabrication, straightforward device operation, and precise, predictable, and programmable flow-rate generation as an open-source pumping tool. Controlling the OS pipette using an open-source microcontroller board not only allows straightforward generation of constant flow rates with simple source code commands, but also permits varying flow rates to be programmed (including stepwise increase and decrease of the flow rate over time, and flow-rate pulse generation). We successfully validate the OS pipette's capabilities for portable microfluidic cell separation and counting. The OS pipette has promise as a rapidly evolving and potentially transformative pumping tool that freely allows unrestricted use, distribution, reproduction, and modification even by non-expert users, and further enables diverse usages, even beyond microfluidics.
Bibliographic details
Access and metrics
Topics and keywords
Funding
- National Research Foundation of Korea · 2016R1A5A1010148
- National Research Foundation of Korea · 2019R1H1A1079944
Perspective and practical signals
Why it matters
No narrative note curated yet.
Limitations